TITLE 77: PUBLIC HEALTH
CHAPTER I: DEPARTMENT OF PUBLIC HEALTH
SUBCHAPTER r: WATER AND SEWAGE
PART 905 PRIVATE SEWAGE DISPOSAL CODE
SECTION 905.APPENDIX A ILLUSTRATIONS AND EXHIBITS



Section 905.APPENDIX A   Illustrations and Exhibits

 

Section 905.ILLUSTRATION X   Illinois Raised Filter Bed

 

Section 905.EXHIBIT A   Sizing Requirements<br>Section 905.EXHIBIT B   Batch Treatment Aeration Tank Design Requirements<br> Section 905.EXHIBIT C   Filter Bed Cross Section (Side View)<br> Section 905.EXHIBIT D   Filter Bed Cross Section (End View)<br> Section 905.EXHIBIT E   Sizing Requirements Using Soils Investigation Information

 

 

RESIDENTIAL

NON-RESIDENTIAL

U.S./GALS

BEDS 4 GAL/SQ FT Minimum SQ FT

SUGGESTED BED SIZE Minimum

BEDS

2.5 GALS/SQ FT Minimum SQ FT

SUGGESTED BED SIZE Minimum

300

75 SQ/FT

7'6" X 10'0"

120 SQ/FT

10'0" X 12'0"

450

112.5 SQ/FT

10'0" X 11'3"

180 SQ/FT

12'0" X 15'0"

500

125 SQ/FT

10'0" X 12'6"

200 SQ/FT

12'0" X 17'0"

600

150 SQ/FT

12'0" X 12'6"

240 SQ/FT

15'0" X 16'0"

800

200 SQ/FT

12'0" X 16'8"

320 SQ/FT

16'0" X 20'0"

1,000

250 SQ/FT

12'0" X 21'0"

400 SQ/FT

20'0" X 20'0"

1,100

275 SQ/FT

12'6" X 22'0"

440 SQ/FT

20'0" X 22'0"

1,200

300 SQ/FT

15'0" X 20'0"

480 SQ/FT

20'0" X 24'0"

1,300

325 SQ/FT

15'0" X 22'0"

520 SQ/FT

20'0" X 26'0"

1,400

350 SQ/FT

18'0" X 20'0"

560 SQ/FT

20'0" X 28'0"

1,500

375 SQ/FT

18'0" X 21'0"

600 SQ/FT

20'0" X 30'0"

1,600

 

 

640 SQ/FT

2 @ 16'0" X 20'0"

1,700

 

 

680 SQ/FT

2 @ 17'0" X 20'0"

1,800

 

 

720 SQ/FT

2 @ 18'0" X 20'0"

2,000

 

 

800 SQ/FT

2 @ 20'0" X 20'0"

2,100

 

 

840 SQ/FT

2 @ 20'0" X 21'0"

2,200

 

 

880 SQ/FT

2 @ 20'0" X 22'0"

2,400

 

 

960 SQ/FT

2 @ 20'0" X 24'0"

2,500

 

 

1,000 SQ/FT

2 @ 20'0" X 25'0"

3,000

 

 

1,200 SQ/FT

2 @ 24'0" X 25'0"

12,000

 

 

4,800 SQ/FT

8 @ 24'0" X 25'0"

 

(Source:  Old Illustration X repealed at 9 Ill. Reg. 20738, effective January 3, 1986; new Illustration X added at 27 Ill. Reg. 3074, effective February 10, 2003)


 

Section 905.APPENDIX A   Illustrations and Exhibits

 

Section 905.ILLUSTRATION X   Illinois Raised Filter Bed

 

Section 905.EXHIBIT B   Batch Treatment Aeration Tank Design Requirements

 

 

 

(Source:  Added at 27 Ill. Reg. 3074, effective February 10, 2003)


 

Section 905.APPENDIX A   Illustrations and Exhibits

 

Section 905.ILLUSTRATION X   Illinois Raised Filter Bed

 

Section 905.EXHIBIT C   Filter Bed Cross Section (Side View)

 

 

 

(Source:  Added at 27 Ill. Reg. 3074, effective February 10, 2003)


Section 905.APPENDIX A   Illustrations and Exhibits

 

Section 905.ILLUSTRATION X   Illinois Raised Filter Bed

 

Section 905.EXHIBIT D   Filter Bed Cross Section (End View)

 

 

NOTE: CROWNING SHOWN FOR TORPEDO SAND APPLIES TO MANTLE AREA ONLY

 

 

 

(Source:  Added at 27 Ill. Reg. 3074, effective February 10, 2003)


Section 905.APPENDIX A   Illustrations and Exhibits

 

Section 905.ILLUSTRATION X   Illinois Raised Filter Bed

 

Section 905.EXHIBIT E   Sizing Requirements Using Soils Investigation Information

 

 

Design Group

Percolation Rate Equivalent

I

Unsuitable

II

10 minutes/inch

III

15 minutes/inch

IV

20 minutes/inch

V

23 minutes/inch

VI

25 minutes/inch

VII

30 minutes/inch

VIII

35 minutes/inch

IX

40 minutes/inch

X

50 minutes/inch

XI

70 minutes/inch

XII

90 minutes/inch

 

(Source:  Added at 27 Ill. Reg. 3074, effective February 10, 2003)