TITLE 32: ENERGY
CHAPTER II: ILLINOIS EMERGENCY MANAGEMENT AGENCY
SUBCHAPTER b: RADIATION PROTECTION
PART 346 LICENSES AND RADIATION SAFETY REQUIREMENTS FOR IRRADIATORS
SECTION 346.670 ENTERING AND LEAVING THE RADIATION ROOM


 

Section 346.670  Entering and Leaving the Radiation Room

 

a)         Upon first entering the radiation room of a panoramic irradiator after an irradiation, the irradiator operator shall use a survey meter to determine that the source has returned to its fully shielded position.  The operator shall check the functioning of the survey meter with a radiation check source prior to entry.

 

b)         Before exiting from and locking the door to the radiation room of a panoramic irradiator prior to a planned irradiation, the irradiator operator shall:

 

1)         Visually inspect the entire radiation room to verify that no one else is in it; and

 

2)         Activate a control in the radiation room that permits the sources to be moved from the shielded position only if the door to the radiation room is locked within a pre-set time after setting the control.

 

c)         During a power failure, the area around the pool of an underwater irradiator may not be entered without using an operable and calibrated radiation survey meter, unless the over-the-pool monitor required by Section 346.290(b) is operating with backup power.

 

(Source:  Amended at 47 Ill. Reg. 9201, effective June 22, 2023)